INTRODUCTION DK-2866 MK-II+ is a self-contained full feature digital access control keypad that combines proximity EM card reader in one unit. The keypad can plug in Wi-Fi Module (AP-01 / AP-02) as a Wi-Fi Keypad. The keypad has three outputs. The output 1 is a solid state relay selectable to drive Fail-safe or Fail-secure electric lock. Solid state relay gives longer service life and prevents sabotage of energizing the output relay to open the door with a strong magnet. The output 2 is a standard relay with N.C. and N.O. dry contacts for auxiliary controls. The output 3 is a transistor open collector output with maximum sink current of 100mA for driving auxiliary device. It also has a N.O. relay dry contact output for driving an external door bell. The keypad is employing the Tri-Tech design approach capable for system expansion. It works perfectly in stand alone operation, split-decoded operation for security enhancement with the optional decoder, and multi-station operation for user convenience with the auxiliary keypad-readers. The keypad is ideal for access control and alarm system arm-disarm control. It is also a programmable industrial timer (from 1 second to over 24 hours) for automatic operator system. Demo Video: https://fb.watch/9hP4CdHEE-/
Output 1 : Solid State Relay Output for Fail-safe or Fail-secure Electric Lock Output 2 : Standard N.C. & N.O. Dry Relay Contacts Output 3 : Solid State Open Collector Output Bell Button : N.O. Dry Relay Contact FEATURES
Three Output Full Feature Digital Keypad for Door Lock and Equipment Controls Tact Switch Keyboard 12VDC Operation, Compatible with Fail-safe or Fail-secure Electric Door Lock 3A / 16VDC Maximum Power Rating Solid State Door Lock Driver for Long Service Life Built-in Real-Time-Clock Controls The Start and Stop Times in Daily Operation Stand-alone, Split-decoded and Multi-station Tri-Tech Operations ompatible with The Auxiliary Reader, Auxiliary Keypad and Split-decoder for System Expansion Simply with Single Wire Connection of Their Common Data I/O Bus User Code, EM Card and EM card + User Code Concurrent Operations Compatible with 125 Khz Manchester 64-bit EM4100 & EM4200 EM Cards and Keyfobs 26-bit, 34-bit or 37-bit Wiegand Data Output Format Selectable 1A/24V DC Contact Rating Form C Relay for Output 2 and Open Collector for Output 3 Built-in Bell Button with 1A/24V Rating N.O. Dry Contact for External Door Chime Actuation Built-in Control Logic Circuit for High Security Dual Door Inter-lock System Timing Re-lock or Auto Re-lock for The Door After Entry Prevents “Tail-gate” Follower Door Forced Open Warning and Door Propped-up Warning Maximum 1,000 Users for Controlling Output 1 and 100 Users Each for Outputs 2 and 3 Multi-task Super User Code for Inhibiting (Refuse Access), Overriding Door Lock (Keep Door Open); and Operating The Outputs at Any Time And under Any Condition for Safety Duress Code for Door Opening and at The Same Time Reporting The Event of Duress 50 Visitor Codes for Temporary Workers and Visitors, Which Expire after Use or The Programmable Time of 1-99 Hours Three Programming Options for System Safety Lock-up after Successive False Code Entry Outputs Are Configurable with 1-99999 Seconds Auto Reset Mode or Start / Stop Mode. Auto or Manual User Code Entry Mode for User Convenience And Security Enhancement Pacifier Tone And Door Open Announcer Can Be OFF for Silent Environment Standby Flashing LED Indicator Can Be OFF for People Do Not Like Flashing LED at Night Six Egress Delay and Warning Options for User Convenience and Security Enhancement Alarm or Key Button Active Signal Output for Triggering Optional Equipment Built-in Tamper Switch with N.C. Dry Contact Surface Mount Weatherproof Plastic Housing Painted in Metallic Black Color Wi-Fi Module can be plugged in for more features
SPECIFICATIONS Operating Voltage: 12V DC Nominal; 11-15V DC Operating Current: 60mA (quiescent) to 150mA Operation Temperature: -20 C to +70 C Environmental Humidity: 5-95% relative humidity non-condensing Working Environment & Ingress Protection: All weather, IP-55 Number of Users: Output 1 – 1,000 (PINs and/or Cards) + 50 Duress Codes Output 2 – 100 (PINs and/or Cards) + 10 Duress Codes Output 3 – 100 (PINs and/or Cards) + 10 Duress Codes Proximity Card: Standard EM Card or Keyfob, 125Khz Number of Visitor Codes: 50, programmable for one time or with the time limit Timings for Code Entry and Card Reading: 10 seconds waiting for next digit entry 30 seconds waiting for code entry after card reading The Timers: Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1, 2 & 3 Egress Button: Programmable for Instant, Delay with Warning and/or Alarm Momentary or Holding Contact for the Exit Delay Input Sensing Terminals: a) Door position, b) Egress, c) O/P 1 inhibit Output Control Terminals: Transistor Open Collector 24VDC/100mA sink Max for the following outputs a) Duress, b) Alarm, c) Key Active, d) Output 3, e) Inter-lock Output Contact Ratings: Output Relay 1 – Solid State Relay, Fail-safe or Fail-secure selectable, 3A/16 VDC Max. Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max. Door Bell Relay – N.O. dry contact, 1A/24VDC Max. Tamper Switch – N.C. dry contact, 50mA/24VDC Max. Dimensions: 126(H) X 75(W) X 35-40(D)mm Weight: 200g net Housing: ABS Plastic box
Specifications are subject to change for modification without notice
|