Ordering Number: HA-263D-T (Alarm Control Panel with Built-in Power Transformer) HA-263D (Alarm Control Panel without Built-in Power Transformer) NOTE: HA-263D is the replacement of the following OBSOLETE models: 1) HA-982-R/S-1, 2) HA-982J-R/S-1, 3) HA-981-R/S-1, 4) HA-871, HA-872, 5) HA-841D 6) HA-863RD
Arm-disarm Controlled by Digital Keypad
8 Zones in Two Partitions
Independently Programmable User Codes for Partition 1, 2, & The Whole System
User Codes Can Be 4-6 Digits
Programmable Time for Entry Delay and Alarm Duration
Each Protection Zone is Independently Programmable for Response Time
Exit and Entry Warning Beeps On-Off Options
Arm-Disarm Ring Back Indication On-Off Options
Instant Arming Codes for Home and Away Operations
Built-in Dynamic Battery Charger and Tester with Auto or Manual Testing
On Board Software Zone for Panic Alarms
Maximum 4 Control Keypads or Key Switches Can Be Connected
Home or Away Operation
Forced to Arm with The Faulty Zone(s) Bypassed
Handover Option for The Instant Zones
Facilities for Driving Siren/Bell, Satellite Siren and Strobe Light
Power Low Watchdog Resets System
Non-Volatile Memory
12V / 6.5Ah Back-up Battery (Not Included)
16.5VAC Operation
Weight: 2.5 Kg (The Control Panel & The Keypad)
Dimensions: 270(H) X 265(W) X 78(D) mm (The Control Panel); 117(H) X 117(W) X 27(D) mm (The Keypad)
STATUS: Mass Production
Ordering Number: HA-263K-T (Alarm Control Panel with Built-in Power Transformer) HA-263K (Alarm Control Panel without Built-in Power Transformer) NOTE: HA-263K is the replacement of the following OBSOLETE models: 1) HA-841 2) HA-863RK
Arm-disarm Controlled by Key Switch Control Station
8 Zones in Two Partitions
Independent Control for Partition 1, 2, & The Whole System
Programmable Time for Entry Delay and Alarm Duration
Protection Zones Are 500mS Response Time
Exit and Entry Warning Beeps On-Off Options
Arm-Disarm Ring Back Indication On-Off Options
Built-in Dynamic Battery Charger and Tester with Auto Testing
Maximum 4 Control Keypads or Key Switches Can Be Connected
Forced to Arm with The Faulty Zone(s) Bypassed
Handover Option for The Instant Zones
Facilities for Driving Siren/Bell, Satellite Siren and Strobe Light
Power Low Watchdog Resets System
Non-Volatile Memory
12V / 6.5Ah Back-up Battery (Not Included)
16.5VAC Operation
Weight: 2.5 Kg (The Control Panel & The Key Switch Station)
Dimensions: 270(H) X 265(W) X 78(D) mm (The Control Panel); 117(H) X 73(W) X 43(D) mm (The Key Switch Station)
STATUS: Mass Production
|