DK-2832 A/B MK-II : THREE OUTPUT VANDAL RESISTANT FULL FEATURE TRI-TECH KEYPAD
 
Product Information

 INTRODUCTION 

DK-2832 is a self-contained three output, vandal resistant and weatherproof keypad. It has been designed for full feature stand alone access control applications. It is expandable to work with an optional decoder (DA-2800 or DA-2801) for high security split-decoded operation. It is also compatible with the auxiliary card reader (AR-2802) and the auxiliary keypad readers (AR-2806, AR-2807 and AR-2809) for upgrading a stand alone or split-decoded system to multi-station operation.
The keypad is ideally for door strike and alarm arm-disarm controls. It is also a programmable industrial timer (from 1 second to over 24 hours) for automatic operator system.

DK-2832A – Output Relay 1 & 2 Controlled by User Codes
DK-2832B – Output Relay 1 Controlled by User Codes; Output 2 by Bell Button

Output 3 is an open collector output controlled by user codes in both models.

 

 FEATURES 

  • Three Output Full Feature Digital Keypad for Door Lock and Equipment Controls

  • 12-24V DC Auto Adjusted Wide Operation Voltage Range

  • Built-in Real-Time-Clock Controls The Start and Stop Times in Daily Operation

  • Stand-alone, Split-decoded and Multi-station Tri-Tech Operations

  • Compatible with The Auxiliary Reader, Auxiliary Keypad and Split-decoder for System Expansion Simply with Single Wire Connection of Their Common Data I/O Bus

  • Accepts 125 Khz EM Card Operation Via Optional Auxiliary Card Reader

  • 26-bit, 34-bit or 37-bit Wiegand Data Output Format Selectable

  • Compatible with Fail-safe or Fail-secure Electric Door Lock

  • 5A / 24VDC Contact Rating Form C Relay for Output 1, 1A/24V DC Form C Relay for Output 2 and Open Collector for Output 3

  • Built-in Control Logic Circuit for High Security Dual Door Inter-lock System

  • Timing Re-lock or Auto Re-lock for The Door After Entry Prevents “Tail-gate” Follower

  • Door Forced Open Warning and Door Propped-up Warning

  • Maximum 1,000 Users for Controlling Output 1 and 100 Users Each for Outputs 2 and 3

  • Multi-task Super User Code for Inhibiting (Refuse Access), Overriding Door Lock (Keep Door Open); and Operating The Outputs at Any Time and under Any Condition for Safety

  • Duress Code for Door Opening and at The Same Time Reporting The Event of Duress

  • 50 Visitor Codes for Temporary Workers and Visitors, Which Expire after Use or The Programmable Time of 1-99 Hours

  • Three Programming Options for System Safety Lock-up after Successive False Code Entry

  • Outputs Are Configurable with 1-99999 Seconds Auto Reset Mode or Start / Stop Mode.

  • Auto or Manual User Code Entry Mode for User Convenience And Security Enhancement

  • Pacifier Tone And Door Open Announcer Can Be OFF for Silent Environment

  • Standby Flashing LED Indicator Can Be OFF for People Do Not Like Flashing LED at Night

  • Six Egress Delay and Warning Options for User Convenience and Security Enhancement

  • Alarm Signal Output for Triggering Optional Equipment

  • Built-in Tamper Switch with N.C. Dry Contact

  • Standard and Door Bell Button (Using Output 2 as Bell Actuation Contact) Versions Available

  • Vandal Resistant Weatherproof Keypad with Back-lit Metal Key Buttons

  • Die-Cast Metal Faceplate Supplied with Flush Mount Plastic Back Box

 

 SPECIFICATIONS 

  • Operating Voltage:
    12V-24V DC, Auto adjusting

  • Operating Current:
    60mA (quiescent) to 150mA

  • Operation Temperature:
    -20 C to +70 C

  • Environmental Humidity:
    5-95% relative humidity non-condensing

  • Working Environment & Ingress Protection:
    All weather, IP-66

  • Number of Users:
    Output 1 – 1,000 (Codes) + 50 Duress Codes
    Output 2 – 100 (Codes) + 10 Duress Codes (DK-2832A only)
    Output 3 – 100 (Codes) + 10 Duress Codes

  • Number of Visitor Codes:
    50, programmable for one time or with time limit

  • Timings for Code Entry:
    10 seconds waiting for next digit entry

  • The Timers:
    Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1, 2 & 3

  • Egress Button: 
    Programmable for Instant, Delay with Warning and/or Alarm
    Momentary or Holding Contact for Exit Delay

  • Input Sensing Terminals:
    a) Door position, b) Egress, c) O/P 1 inhibit

  • Output Control Terminals:
    Transistor Open Collector 24VDC/100mA sink Max for the following outputs
    a) Duress, b) Alarm, c) Output 3, d) Inter-lock

  • Output Contact Ratings:
    Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
    Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
    Output 3 – open collector, 24VDC/100mA sink Max.

    Tamper Switch – N.C. dry contact, 50mA/24VDC Max.

  • Dimensions:
    120(H) X 80(W) X 50(D)mm

  • Weight:
    460g net

  • Housing:
    Zinc alloy die-casting faceplate with sealed plastic back box


Specifications are subject to change for modification without notice.


Back
Related Product
DUAL OUTPUT VANDAL RESISTANT FULL FEATURE TRI-TECH WIFI KEYPAD WITH CARD READER
DUAL OUTPUT VANDAL RESISTANT TRI-TECH WIFI KEYPAD
DUAL OUTPUT VANDAL RESISTANT FULL FEATURE TRI-TECH WIFI KEYPAD
DUAL OUTPUT VANDAL RESISTANT FULL FEATURE TRI-TECH KEYPAD
VANDAL RESISTANT FULL FEATURE SPLIT-DECODED KEYPAD KIT
 
 

Website design powered by WOW Creative Ltd